Home / IN DUCTS

IN DUCTS

IKС...–Т... Central tube optical fibre cable for duct installation

INTEGRA optical fibre cables are designed for the installation in telecommunicational networks. This type of cables can be buried in the grounds of the 1-3 groups, installed in ducts, over the bridges and overpasses, in tunnels, in sewer ducts, inside the buildings. 

When installed in sewer ducts, in tunnels and inside buildings the outer sheath of the cables should be produces of the flame-proof materials (IKCN, IKCLN, IKCLng) also smoke-free and halogen-free materials (IKCLng(B)-HF).

Optical fibre cables for the installation in ducts IKC... are produced according to TS № 3587–004–95485862–2009.
Special characteristics of optical fibre cables:
Light construction (without intermediate sheathing) — IKCL–… .
Fire-resistant — IKCN–…; IKCLN–(IKSLng(С), IKCLng(В)-HF)… .

Cable type IKC…-Т…
Construction central tube
Number of optical fibres in the cable to 48
Number of tubes 1
Minimum outer diameter, mm 10,3
Minimum weight, kg/кm 110
Minimum long-term tension, кN 1,5
Minimum crush resistance, kN/cm 0,3
Minimum allowed impact resistance, J 10
Minimum bending radius 20 Ø OD
Operating teperature range, °С from -50 to +50
Minimum Installation temperature, °С -30

IKC-Т-А12-2.5

IK – INTEGRA-CABLE optical fibre cable
С – armoured with bouble plastic coated corrugated steel tape
Т – central tube
А – optical fibre type (single-mode, ITU-T G.652.С(D))
12 – number of optical fibres in the cable
2.5 – maximum tension allowed, kN

  • The operating temperature range can be extended from –60°С to +70°С.